|
aHR0cDovL2ZyZWVzaGlwLmNvLmty
- À¯Çü: ±âŸ
- ±Ù¿ø: CN (Á¤Ç°)
- Display: 3.5 in color TFT
- Resolution: 320*480
- Indicator: Alarm indicator, Power indicator.
- Trace: 1 plethysmogram waveform.
- Alarm: Probe off, low power.
Models and Configurations H4S = SpO2 only H4T = SpO2 + NIBP + TEMP H4C = SpO2 + Main Stream CO2 H4SC = SpO2 + Side StreamCO2 H4E = SpO2 + NIBP + Main Stream EtCO2 H4SE = SpO2 + NIBP + Side Stream EtCO2 Feature 1. Accurate measurement in 0.05% low perfusion index. 2. Provide the parameter of PI(Perfusion Index 0.05%-20%). 3. Accurate measurement in all kind of animal such as dog, cat, rat, rabbit. Etc. 4. NIBP adopt. 5. SAWAA(Self-Adaptive-Waveform-Amplitude-Adjust) algorithm and SAFD (Self Adaptive-Fast-Deflation) algorithm. 6. Easy Operation. 7. Powerful data backup capacity up to 100 users ID record, supporting historical data review and trend chart back checking. 8. Two measurements mode: Spot, Monitoring. 9. Support audio and visual alarm, support to set alarm upper/lower limit values. 10. Lithium-ion batter power supply. 11. Standard charging dock. Performance Specification: Display: 3.5¡¯¡¯ color TFT Resolution: 320*480 Indicator: Alarm indicator, Power indicator. Trace: 1 plethysmogram waveform. Alarm: Probe off, low power. SPO2 Measure range: Sp02: 0-100% PR: 0-500bpm Perfusion index: 0.05%-20% Accuracy range: Sp02 saturation: 70-100% Pulse rate: 20-500BPM Perfusion lndex: 0.025%-20% Measurement accuracy Sp02: Big animal (including pediatric)+ 2digit (70-100%) not defined (<70%) Small animal + 3 digits not defined (<70% ) On motion condition + 3digit PR: big/small animal (including pediatric)+ 3digits On motion condition+ 3digit Perfusion lndex:0.05%-20% Resolution Sp02 saturation: 1 % Pulse rate: 1 BPM NIBP * Pulse rate range: 40-240bpm * NIBP measurement accuracy: ¡¾3mmHg * Pulse rate measurement accuracy: <=2% (>=100 8PM) or 2 beats/min (<100 8PM) * Independent software protection pressure * Big animal: 300mmHg Small animal: 300mmHg * Independent hardware protection pressure * Big animal: 320-330mmHg Small animal: 320- 330mmHg TEMP ¡¤Measurement range: 25-45¡ÆC ¡¤Resolution: 0.1¡ÆC Accuracy: 0.1¡ÆC ¡¤Power Type: Lithium ion battery ¡¤Operation time: 8 hours for normal operation ¡¤Temperature:Operating: 0¡ÆC-45¡ÆC Storage/Transportation:-20¡ÆC-65¡ÆC ¡¤Humidity: Operating: 15% to 90% noncondensing ¡¤Storage: 0% to 95% noncondensing ¡¤Altitude: Operating Altitude: Up to 5000 meters ¡¤SIZE: Dimension 146mm*67mm*30mm Weight 250g EtCO2 ETC02: 0-150mmHg (0-19.7%) (0-20kPa ) RR: 3-150BPM RR Accuracy: ¡¾1BPM ETC02: 0.1 mmHg RR:1BPM Setting compensation parameters Pressure range: 450-850mmHg Oxygen range: 0-100% Equilibrium gas: N20,He Power Requirements: 5.0vdc ¡¾5%, 1A(Module average power consumption is less than 1.3W) Temperature: Work Environment: 10 - 40¡ÆC Storage Environment: -40 - 70¡ÆC Humidity: Work Environment: 10% - 90% RH Storage Environment: <90% RH
|
|
|
|
|