|
aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ½º¸¶Æ® ±â±â: no
- ÃøÁ¤ À¯Çü: K
- ³ª»ç: M12 * 1.5
- ÄÉÀÌºí ±æÀÌ: 1M
- À¯Çü: K
- ÀÌ·Ð: ¿Âµµ Á¶Àý±â
- »ç¿ë¹ý: Indoor
- ¸ðµ¨ ¹øÈ£: STC-3008
- ÃÖ´ë ÃøÁ¤ ¿Âµµ: 49 ¡Æ ¹× ¹Ø¿¡
- ´ëÇü È°ÀÚ: DIGITAL
- Èû À¯Çü: ÃæÀü±â
- µð½ºÇ÷¹ÀÌ Å©±â: 1.9 ÀÎÄ¡ ¹× ¹Ø¿¡
- ÀÛdz: ½ºÅĵù ¹× º®°ÉÀÌ
- ºê·£µå À̸§: RUIBOZHI
- ±Ù¿ø: CN (Á¤Ç°)
- Temperature control range: -50¡ÆC-100¡ÆC
- Temperature control accuracy: ¡¾1¡ÆC
- Power supply: DC 12V DC 24V AC 110-220V
¿É¼ÇÁ¤º¸[(350850)STC-3008 DC 12V][(350852)STC-3008 DC 24V][(350853)STC-3008 AC 110-220V]
Description
1.Automatic conversion of refrigeration and heating mode 2.Control mode of return difference;Temperature display resolution 0.1 3.The temperature controller has the characteristic of high accuracy, high sensitivity, high stability. 4.Support temperature correction and support for power loss (the parameters of the sudden power failure are still valid 5.Application range is like home temperature control, farm, various cold storage, greenhouse, aquarium, etc Display Type:Digital Style:Standing Station Temperature sensor: NTC 10K Senor length:1.0m Temperature measuring range: -55 ° C ~ 120 ° C Resolution: 0.1 ° C Accuracy:±1° C Power supply: 110-220VAC 50/60Hz, 12V DC , 24V DC(Please choose power supply when ordering) Power consumption: <3W Storage temperature: -30 ° C ~ 75 ° C Relative humidity: 20% ~ 85% (No condensate) Relay contact capacity: Two Relay Cool 10A/240VAC; Heat 10A/240VAC Set startup temperature: Press the "up" button once to display the starting temperature. Long press the "up" button for about 3 seconds,The required temperature can be set by the up and down keys Set the stop temperature: Press the button once to display the stop temperature. Long press the button for about 3 seconds and the stop temperature number flashes. The required temperature can be set by the up and down keys Press "Up 1" Button & "Up 2"Button at the same time to setting mode Default P0 ¨ç: Delay start 0-60 minutes 0 P1 ¨è: Delay start 0-60 minutes 0 P2 High temperature alarm P3~120°C 120°C P3 Low temperature alarm P2~-55°C -55°C How to restore factory Settings press the "Down 1" and "Down 2" button at the same time, the factory setting is restored Temperature correction Press ¡°Up 1 ¡±and ¡°Down 1 ¡±at the same times for 3 second. positive value = measured value + corrected value(group 2 temperature correction is the same method ) Heating Mode--Start temperatureStop temperature You can set 1 heating 1 cooling or 2 cooliong or 2 heating. Package: 1X Temperature Controller 2X Waterproof Sensor
|
|
|
|
|